CVE-2026-99114
In the Linux kernel, the following vulnerability has been resolved: ksmbd: initialize FileSystemControlFlags in FS_CONTROL_INFORMATION smb2_get_info_filesystem() reports 48 bytes for FS_CONTROL_INFORMATION, that is the whole of struct smb2_fs_control_info, but never assigns FileSystemControlFlags. Those four bytes go to the client as they are found in the response buffer. The buffer is zeroed on allocation, so a standalone request leaks nothing. A compound request can leak: the offset of the next response is advanced by the length pinned for the previous one, so a reply that was written into the buffer and then dropped in favour of the short error response of smb2_set_err_rsp() stays there, and the next reply is laid over it with only the header cleared. ksmbd does not implement quota tracking, so report no control flags.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.