Evidence-led vulnerability intelligence · 2026-10-23 18:47 IST

CVE-2026-99060

In the Linux kernel, the following vulnerability has been resolved: wifi: mt76: mt7603: initialize global station WCID mt7603 uses a driver-private global station WCID for frames that have neither a station nor a vif, including frames injected through a monitor interface. Unlike the core global WCID initialized by mt76_register_device(), this WCID is published without ever being passed to mt76_wcid_init(). Since commit 0335c034e726 ("wifi: mt76: fix race condition related to checking tx queue fill status"), mt76_tx() queues every such frame on the WCID's tx_pending or tx_offchannel queue and links its tx_list. The first injected frame therefore reaches __skb_queue_tail() with an uninitialized sk_buff_head and dereferences a NULL prev pointer. Initialize the WCID before publishing it. The fix was tested on an MT7603 PCIe device. Three wildcard probe requests were injected through a monitor interface. The hardware queue head and tail advanced from 0 to 3 and a second radio captured the third request over the air. No oops or reset occurred. After restoring AP mode, a 150 MB transfer also completed without a reset.

UNRATED · N/ALinux

Executive briefing

The source record describes: In the Linux kernel, the following vulnerability has been resolved: wifi: mt76: mt7603: initialize global station WCID mt7603 uses a driver-private global station WCID for frames that have neither a station nor a vif, including frames injected through a monitor interface. Unlike the core global WCID initialized by mt76_register_device(), this WCID is published without ever being passed to mt76_wcid_init(). Since commit 0335c034e726 ("wifi: mt76: fix race condition related to checking tx queue fill status"), mt76_tx() queues every such frame on the WCID's tx_pending or tx_offchannel queue and links its tx_list. The first injected frame therefore reaches __skb_queue_tail() with an uninitialized sk_buff_head and dereferences a NULL prev pointer. Initialize the WCID before publishing it. The fix was tested on an MT7603 PCIe device. Three wildcard probe requests were injected through a monitor interface. The hardware queue head and tail advanced from 0 to 3 and a second radio captured the third request over the air. No oops or reset occurred. After restoring AP mode, a 150 MB transfer also completed without a reset. The practical risk depends on whether an affected product/version is present, reachable and configured in an exploitable way. Review the affected-product evidence and linked vendor advisories before assigning exposure status.

Assessment: Potential exposure only — validate the installed product, exact version, configuration and vendor applicability before treating an asset as confirmed vulnerable.

Evidence confidence: Low Evidence-derived, not an exploitability verdict

Severity & attack characteristics

N/A / 10 ·

CVSS vector:

No CVSS vector is currently available in the source record.

Technical explanation & impact

The technical mechanism is not expanded beyond the source description unless a referenced advisory supplies additional evidence. Read the linked vendor/CERT advisories for root-cause detail.

Potential impact must be interpreted from the published CVSS impact metrics and the affected component. A CVSS impact score is not proof that a particular asset is exploitable.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Information gaps & confidence notes

These gaps indicate missing source data. CVE Watch does not fill them with guessed product, exploit or patch details.

Last enrichment: 2026-11-05T14:04:27+00:00 · Source last modified: 2026-10-23T13:17:29.753

Open NVD record ← Back to CVE Watch