CVE-2026-98399
In the Linux kernel, the following vulnerability has been resolved: s390/ipl: Fix NULL deref in dump_reipl without re-IPL parm block Unlike kdump, which passes the re-IPL parameter block through os_info, the stand-alone dump passes it through the IPL parm block address and checksum in lowcore. Some IPL types, like HMC FTP boot or QEMU direct kernel boot, might not provide an IPL parameter block. In this case reipl_type_init() selects IPL_TYPE_UNKNOWN and reipl_block_actual remains NULL. Nevertheless, dump_reipl_run() unconditionally dereferences it when preparing the lowcore fields. This may happen to work by chance when address zero contains readable lowcore data. A zero IPL parameter block address is then stored in lowcore, causing the stand-alone dumper to enter disabled wait after completing the dump. Explicitly store a zero IPL parameter block address and checksum when no re-IPL parameter block is available. This does not change the behavior: the stand-alone dumper completes the dump and halts, while valid re-IPL parameter blocks continue to be handled as before.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.