Evidence-led vulnerability intelligence · 2026-10-06 14:48 IST

CVE-2026-98215

In the Linux kernel, the following vulnerability has been resolved: selinux: preserve user SID across nested backing files SELinux saves the user file SID in a backing-file security blob so it remains available after mmap() replaces vma->vm_file with a backing file. For nested backing files (overlayfs over overlayfs, or FUSE passthrough backed by overlayfs), user_file may itself be a backing file. Its fsec->sid is the SID of the mounter that opened it, rather than the user that opened the top-level file. mprotect() then checks fd { use } against the mounter SID. This can incorrectly deny access without a domain transition, or check the wrong target SID after one. Copy the saved user SID when user_file is a backing file. Keep using the regular file SID for the first backing layer. With two nested overlayfs mounts and SELinux enforcing, mprotect(PROT_READ) returns EACCES with an fd { use } denial against the mounter SID. With this change, mprotect() succeeds. Tested on arm64 QEMU with a small BusyBox initramfs and a purpose-built SELinux policy. The original test was also repeated with Fedora Cloud Base 44 userspace and gave the same result.

UNRATED · N/ALinux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

N/A / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch