CVE-2026-97441
In the Linux kernel, the following vulnerability has been resolved: ata: ahci: fail probe if BAR too small for claimed ports When an AHCI controller is disabled in BIOS, its HOST_CAP register may contain a bogus value, e.g. 0xFFFFFFFF. Since CAP.NP (Number of Ports) is a zeroes based 5-bit register field, a value of 0x1f means 32 ports. If CAP.NP claims more ports than can physically fit within the mapped BAR region, accessing port registers beyond the BAR boundary causes a kernel panic. Add validation in ahci_init_one() to check that the BAR size is sufficient for the number of ports claimed in CAP.NP. The check calculates the required MMIO size as: required_size = 0x100 (global registers) + max_ports * 0x80 If required_size exceeds the actual BAR size, the probe fails with -ENODEV, preventing the panic and providing a clear error message. [cassel: commit log]
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.