Evidence-led vulnerability intelligence · 2026-11-18 01:47 IST

CVE-2026-95822

The SOCKS5 client in subsys/net/lib/socks/socks.c built the CONNECT request in socks5_tcp_connect() by choosing the SOCKS5 address type from the address family of the proxy (proxy->sa_family) while reading the bytes out of the destination address supplied to connect(). A SOCKS5 request encodes the destination independently of the transport used to reach the proxy, so the two families are unrelated and nothing in the path forces them to agree: set_context_proxy() only requires the proxy family to match the socket, and zsock_connect_ctx() enters the SOCKS branch before any destination validation. With an IPv6 proxy and an AF_INET destination the code treated an 8-byte struct net_sockaddr_in as a struct net_sockaddr_in6 and copied the 16-byte sin6_addr from it, reading 12 bytes past the end of the object and transmitting them to the proxy. With CONFIG_USERSPACE enabled, z_vrfy_zsock_connect() copies only addrlen user bytes into a stack-resident struct net_sockaddr_storage and enforces no per-family minimum length, so the oversized read stays within the storage but returns stale, uninitialised kernel-stack bytes. An unprivileged user-mode thread can therefore open an AF_INET6 stream socket, point setsockopt(SO_SOCKS5) at a proxy it controls, and call connect() with a short AF_INET destination to have the kernel send it 12 bytes of supervisor stack residue per attempt. Without CONFIG_USERSPACE the read runs past the end of the caller's own struct net_sockaddr_in, disclosing adjacent memory to the proxy; the family mismatch can arise unintentionally when a destination is obtained from DNS while an IPv6 proxy is configured. Impact is limited to information disclosure of at most 12 bytes per connect() call, with no write primitive; the leak is delivered to whoever operates the SOCKS5 proxy. The mirrored pairing (IPv6 destination through an IPv4 proxy) is memory-safe but encoded the destination as SOCKS5_ATYP_IPV4 from the first four bytes of the IPv6 address, causing the proxy to connect to an unrelated host. Exploitation requires the non-default CONFIG_SOCKS option, a socket with SO_SOCKS5 configured, and both IPv4 and IPv6 support in the image. The fix moves the encoding into a helper that selects the address type from dest->sa_family and validates dest_len against the matching struct net_sockaddr_in/struct net_sockaddr_in6 before copying, rejecting under-length or unsupported destinations with an error.

LOW · 3.3Linux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

3.3 / 10 · 3.1

CVSS vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Attack vectorL
Attack complexityL
Privileges requiredL
User interactionN
ScopeU
Confidentiality impactL
Integrity impactN
Availability impactN

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch