CVE-2026-91007
The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
- https://github.com/zephyrproject-rtos/zephyr/commit/5467b7a73fe093d7e9562ee15c321cf8f1639d17 VENDOR vulnerabilities@zephyrproject.org
- https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-jr35-f52j-fm88 VENDOR vulnerabilities@zephyrproject.org