CVE-2026-90386
In the Linux kernel, the following vulnerability has been resolved: i3c: dw: avoid shift-out-of-bounds when DAA assigns no devices On an empty bus ENTDAA assigns nothing, so cmd->rx_len (the count of addresses left unassigned) equals master->maxdevs. The GENMASK() index master->maxdevs - cmd->rx_len - 1 then becomes -1, which trips up UBSAN. This happens every time on boot on a Gigabyte/AMD server: UBSAN: shift-out-of-bounds in drivers/i3c/master/dw-i3c-master.c:905:12 shift exponent 64 is too large for 64-bit type 'long unsigned int' CPU: 7 UID: 0 PID: 963 Comm: (udev-worker) Not tainted 7.0.11-200.fc44.x86_64 #1 PREEMPT(lazy) Hardware name: Giga Computing E163-Z34-AAH1-000/MZ33-DC1-000, BIOS R32_F45 04/01/2026 Call Trace: <TASK> dump_stack_lvl+0x5d/0x80 ubsan_epilogue+0x5/0x2b __ubsan_handle_shift_out_of_bounds.cold+0xd7/0x1ab dw_i3c_master_daa.cold+0x1b/0x96 [dw_i3c_master] i3c_master_do_daa_ext.part.0+0x3e/0xf0 [i3c] Skip the mask when no new device was assigned.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.