CVE-2026-89854
In the Linux kernel, the following vulnerability has been resolved: scsi: qla2xxx: Fix cs84xx use-after-free on host teardown qla84xx_put_chip() drops the last reference to ha->cs84xx and frees it via __qla84xx_chip_release() without clearing ha->cs84xx. During teardown it ran before scsi_remove_host(), which is what removes the 84xx_fw_version host sysfs attribute. A concurrent read of that attribute in the window between the two calls executes qla24xx_84xx_fw_version_show(), which dereferences the freed ha->cs84xx, resulting in a use-after-free. Move qla84xx_put_chip() to after scsi_remove_host() in both qla2x00_remove_one() and qla2x00_disable_board_on_pci_error(). Once scsi_remove_host() returns, the sysfs attribute is gone and kernfs has drained any in-flight show(), so no reader can touch cs84xx; the put still runs before the host and ha are freed.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.