Evidence-led vulnerability intelligence · 2026-09-10 19:47 IST

CVE-2026-88887

Renovate is a dependency update automation tool. When listing tags/digests for a container image, Renovate follows pagination links supplied by the remote registry in the HTTP Link header and attaches the registry credentials to the follow-up request without verifying that the pagination URL has the same origin as the original registry. A malicious or compromised container registry can therefore specify a Link header pointing to an attacker-controlled host and receive the credentials Renovate uses for that registry. Exploitation requires that the target has container (Docker) dependencies and is already interacting with the malicious or compromised registry. This is fixed in Renovate 44.11.2 (npm and renovate/renovate images), Mend Renovate CE/EE 15.4.0 and the mend-renovate-enterprise-edition Helm chart 10.4.0; the same-origin check can be disabled with RENOVATE_X_DOCKER_PAGINATION_ALLOW_CROSS_ORIGIN.

CRITICAL · 9.2Containers / DevOps

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

9.2 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch