Evidence-led vulnerability intelligence · 2026-09-04 21:48 IST

CVE-2026-80798

In the Linux kernel, the following vulnerability has been resolved: nfc: llcp: reject PDUs shorter than the LLCP header Every LLCP PDU begins with a two-byte header (DSAP/SSAP + PTYPE), but the receive path never checked that a frame is at least LLCP_HEADER_SIZE bytes before parsing it. nfc_llcp_rx_skb() reads the header via nfc_llcp_ptype()/nfc_llcp_dsap()/ nfc_llcp_ssap(), which dereference pdu->data[0] and pdu->data[1], and a CONNECT or CC PDU then computes tlv_array_len = skb->len - LLCP_HEADER_SIZE; as a size_t and hands it to the TLV walk. When the frame is shorter than the header the subtraction wraps to a huge value and the walk runs far past the buffer, an out-of-bounds read. A nearby NFC device can reach this without authentication; LLCP link activation happens automatically after NFC-DEP. Guard the common receive choke point __nfc_llcp_recv(), shared by both the target (nfc_llcp_data_received()) and initiator (nfc_llcp_recv()) paths, so a short skb is dropped before the rx_work worker parses it. Use pskb_may_pull() rather than a skb->len test so the two header bytes are guaranteed to sit in the skb linear area even for a non-linear skb, matching how the sibling NCI and HCI receive paths validate their headers. Reproduced with a KFENCE out-of-bounds read via /dev/virtual_nci on linux-next. Found by 0sec automated security-research tooling (https://0sec.ai).

UNRATED · N/ALinux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

N/A / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch