CVE-2026-78116
The Broadcom AFBR-S50 time-of-flight sensor driver double-completes an RTIO submission when sensor data evaluation fails. In data_ready_work_handler() (drivers/sensor/broadcom/afbr_s50/afbr_s50.c), a non-STATUS_OK return from Argus_EvaluateData() calls handle_error_on_result(), which finalises the request with rtio_iodev_sqe_err(), but execution then fell through to the tail of the function and finalised the very same struct rtio_iodev_sqe a second time with rtio_iodev_sqe_ok(). Unlike the other error branches in the same function, this one did not return. Both completion helpers reach rtio_executor_done() in subsys/rtio/rtio_executor.c, which returns the submission to the pool via rtio_sqe_pool_free() and, for streaming (multishot) submissions, also releases the RX buffer with rtio_release_buffer(). The second completion therefore reads a freed rtio_iodev_sqe, pushes the same mpsc node onto the submission queue while it is already on the pool free list — splicing the two lists together — and re-submits the freed request so the next measurement is written through an already-released buffer. For one-shot submissions it emits a spurious success completion carrying stale userdata and frees the same pool entry twice. The failure branch is driven by sensor conditions rather than by host software. The vendor API documents statuses such as ERROR_ARGUS_BIAS_VOLTAGE_REINIT and ERROR_ARGUS_LASER_MONITOR_INACTIVE as transient results of harsh ambient light, so a party in front of the optical sensor can provoke the invalid-data condition without any physical contact with the board or any software access; SPI transfer errors reach the same branch. In releases before the payload.Status check was dropped, ordinary sharp distance transitions in the sensor's field of view were sufficient. Impact is corruption of the RTIO submission pool and mempool bookkeeping: aliased submissions, writes through released buffers, and duplicate completions delivered to the application. The attacker does not control the corrupted content, so the practical consequence is memory corruption and loss of availability on devices that instantiate brcm,afbr-s50, rather than directed code execution. Only builds that enable this driver are affected.
Executive briefing
The source record describes: The Broadcom AFBR-S50 time-of-flight sensor driver double-completes an RTIO submission when sensor data evaluation fails. In data_ready_work_handler() (drivers/sensor/broadcom/afbr_s50/afbr_s50.c), a non-STATUS_OK return from Argus_EvaluateData() calls handle_error_on_result(), which finalises the request with rtio_iodev_sqe_err(), but execution then fell through to the tail of the function and finalised the very same struct rtio_iodev_sqe a second time with rtio_iodev_sqe_ok(). Unlike the other error branches in the same function, this one did not return. Both completion helpers reach rtio_executor_done() in subsys/rtio/rtio_executor.c, which returns the submission to the pool via rtio_sqe_pool_free() and, for streaming (multishot) submissions, also releases the RX buffer with rtio_release_buffer(). The second completion therefore reads a freed rtio_iodev_sqe, pushes the same mpsc node onto the submission queue while it is already on the pool free list — splicing the two lists together — and re-submits the freed request so the next measurement is written through an already-released buffer. For one-shot submissions it emits a spurious success completion carrying stale userdata and frees the same pool entry twice. The failure branch is driven by sensor conditions rather than by host software. The vendor API documents statuses such as ERROR_ARGUS_BIAS_VOLTAGE_REINIT and ERROR_ARGUS_LASER_MONITOR_INACTIVE as transient results of harsh ambient light, so a party in front of the optical sensor can provoke the invalid-data condition without any physical contact with the board or any software access; SPI transfer errors reach the same branch. In releases before the payload.Status check was dropped, ordinary sharp distance transitions in the sensor's field of view were sufficient. Impact is corruption of the RTIO submission pool and mempool bookkeeping: aliased submissions, writes through released buffers, and duplicate completions delivered to the application. The attacker does not control the corrupted content, so the practical consequence is memory corruption and loss of availability on devices that instantiate brcm,afbr-s50, rather than directed code execution. Only builds that enable this driver are affected. The practical risk depends on whether an affected product/version is present, reachable and configured in an exploitable way. Review the affected-product evidence and linked vendor advisories before assigning exposure status.
Evidence confidence: Limited Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H
Technical explanation & impact
The technical mechanism is not expanded beyond the source description unless a referenced advisory supplies additional evidence. Read the linked vendor/CERT advisories for root-cause detail.
Potential impact must be interpreted from the published CVSS impact metrics and the affected component. A CVSS impact score is not proof that a particular asset is exploitable.
Weakness classification
CWE-415Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
- https://github.com/zephyrproject-rtos/zephyr/commit/817e92c5184c0d64b8cc6537f4e42ce1e5b635f9 VENDOR vulnerabilities@zephyrproject.org
- https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-559f-34rc-pgw2 VENDOR vulnerabilities@zephyrproject.org
Information gaps & confidence notes
These gaps indicate missing source data. CVE Watch does not fill them with guessed product, exploit or patch details.
- NVD does not currently provide machine-readable vulnerable CPE product/version entries for this record.
Last enrichment: 2026-11-05T06:00:49+00:00 · Source last modified: 2026-11-04T05:19:02.177