Evidence-led vulnerability intelligence · 2026-08-26 20:46 IST

CVE-2026-74745

In the Linux kernel, the following vulnerability has been resolved: eth: bnxt: avoid deadlock when canceling IRQ affinity notifier Unregistering IRQ affinity notifiers waits for the callback synchronously. bnxt takes the netdev instance lock in the notifier (to restart the queue) and cancels the work under the same lock. This may obviously deadlock. Move the restart to the async service task. The queue restart isn't super time sensitive. Store the new TPH tag, schedule the task. Safely canceling the service task is already ironed out. In bnxt_request_irq() the order of registering notifier, affinity and initial TPH programming has to be inverted. I think it was racy previously since user may trigger an update as soon as notifier is installed. There's a small known gap - if pcie_tph_get_cpu_st() fails at init and the target tag is 0 we may miss programming the entry. This does not seem worth fixing, the code has skip-on-failure all over the place, anyway.

HIGH · 7.5Linux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

7.5 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch