CVE-2026-74661
In the Linux kernel, the following vulnerability has been resolved: mac802154: fix netdev use-after-free in beacon worker mac802154_beacon_worker() reads local->beacon_req under RCU and derives the sub-interface from the request, but then drops the RCU read lock and continues to use both sdata and the embedded wpan_dev. mac802154_stop_beacons_locked() cancels only pending beacon work, clears local->beacon_req and frees the request. A beacon worker that is already running can therefore continue after interface teardown and dereference the freed netdev private area. The scan worker already pins the netdev before leaving RCU. Apply the same lifetime rule to the beacon worker: take a netdev reference while the request is still protected by RCU, and release it on all paths that continue after the reference is acquired.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.