CVE-2026-74624
In the Linux kernel, the following vulnerability has been resolved: netfilter: nf_conntrack: defer invalid log until after unlock TCP and SCTP conntrack paths can emit invalid-packet logs while ct->lock is still held. When invalid logging is routed to nfnetlink_log and conntrack export is enabled, the log path can re-enter conntrack netlink glue and dump the same conntrack again. Protocol attribute dumping may take ct->lock, so logging while holding that lock can deadlock. Defer the TCP invalid logs by storing only the minimal log context while ct->lock is held and emitting the log after unlocking. Also make the TCP timeout-lowering invalid path return whether a log is needed, then emit that log after unlocking. Do the same for the SCTP invalid state-transition log that can be reached while ct->lock is held. Add a lockdep assertion to nf_ct_l4proto_log_invalid() so future callers that log invalid conntracks while holding ct->lock are caught outside TCP and SCTP as well.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.