Evidence-led vulnerability intelligence · 2026-08-25 01:47 IST

CVE-2026-72714

Rocq Prover does not restore the universe graph's copy of the universe checking flag when a module that locally disabled the check is closed. Local Unset Universe Checking inside a module is expected to last only until the module ends, and the global flag is restored, but the universe graph keeps its own copy which is left disabled. The two views then disagree: Test Universe Checking reports the check as enabled while the kernel continues to accept universe-inconsistent terms. With the constraint between two universes no longer enforced, Hurkens' paradox applies and yields a proof of False, from which any proposition follows. The proof uses no axioms, plugins or unsafe features once the module has closed, and Print Assumptions reports it as closed under the global context, so neither the assumption audit nor the flag query reflects the actual kernel state. No fix is available.

MEDIUM · 6.8Linux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

6.8 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch