CVE-2026-72703
The guard checker in Rocq Prover treats a parameter of a nested mutual fixpoint as uniform without examining calls between the different bodies of that fixpoint. find_uniform_parameters in kernel/inductive.ml inspects only self-recursive calls, so when no body calls itself the function concludes that every parameter is uniform. A parameter that grows through a cross-call from one body to another therefore keeps the subterm specification it inherited from the enclosing fixpoint, and a recursive call guarded by that specification is accepted although the argument is not structurally smaller. A non-terminating definition is admitted as structurally decreasing, which yields a term whose value equals its own successor and so a proof of False, from which any proposition follows. The proof requires no axioms, plugins or unsafe flags and Print Assumptions reports it as closed under the global context. Introduced in Coq 8.20 and fixed in Rocq 9.2.0.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.