CVE-2026-72164
In the Linux kernel, the following vulnerability has been resolved: ocfs2: avoid moving extents to occupied clusters For non-auto OCFS2_IOC_MOVE_EXT operations, userspace supplies a physical me_goal. ocfs2_move_extent() initializes new_phys_cpos from that goal and expects ocfs2_probe_alloc_group() to replace it with a free run in the target block group. The probe currently leaves *phys_cpos unchanged if the scan reaches the end of the group without finding a free run. An occupied goal at the last bit can therefore survive the probe and be passed to __ocfs2_move_extent(), which copies file data into a cluster still owned by another inode before the bitmap is updated. When the probe does find a free run, it also subtracts move_len from the ending bit. The start of an N-bit run ending at i is i - N + 1, so the current calculation can report the bit immediately before the free run. Clear *phys_cpos before scanning and use the correct free-run start. Callers already treat a zero result as -ENOSPC, so failed probes no longer continue with an occupied caller-controlled goal.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.