Evidence-led vulnerability intelligence · 2026-08-15 11:50 IST

CVE-2026-72007

In the Linux kernel, the following vulnerability has been resolved: pmdomain: imx: Fix i.MX8MP VC8000E power up sequence Per errata[1]: ERR050531: VPU_NOC power down handshake may hang during VC8000E/VPUMIX power up/down cycling. Description: VC8000E reset de-assertion edge and AXI clock may have a timing issue. Workaround: Set bit2 (vc8000e_clk_en) of BLK_CLK_EN_CSR to 0 to gate off both AXI clock and VC8000E clock sent to VC8000E and AXI clock sent to VPU_NOC m_v_2 interface during VC8000E power up(VC8000E reset is de-asserted by HW) Add a bool variable is_errata_err050531 in 'struct imx8m_blk_ctrl_domain_data' to represent whether the workaround is needed. If is_errata_err050531 is true, first clear the clk before powering up gpc, then enable the clk after powering up gpc. [1] https://www.nxp.com/webapp/Download?colCode=IMX8MP_1P33A

UNRATED · N/ALinux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

N/A / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch