CVE-2026-68235
In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: dce100: skip non-DP stream encoders for DP MST On DCE8-class ASICs (e.g. Bonaire), the resource pool contains digital DIG stream encoders plus one analog DAC encoder. When assigning a stream encoder for a second DisplayPort MST stream, if the preferred digital encoder is already acquired, dce100_find_first_free_match_stream_enc_for_link() falls back to the first free pool entry. That entry may be the analog encoder, whose funcs table lacks DP hooks such as dp_set_stream_attribute. The subsequent atomic commit then dereferences NULL function pointers in link_set_dpms_on() and crashes. Skip encoders without dp_set_stream_attribute when the stream uses a DP signal (including MST). Use dc_is_dp_signal(stream->signal) for the MST fallback path instead of checking only the link connector signal. Tested on: - GPU: AMD Radeon R7 260X (Bonaire / DCE8) - Board: Supermicro C9X299-PG300 - Setup: DP MST daisy chain, hotplug second monitor or have it connected on boot - Kernel: 7.1.3 (issue observed since 6.19) - Result: kernel oops without patch; dual monitors stable with patch (cherry picked from commit 28ec64943e3ee4d9b8d30cea61e380f1429953a8)
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.