Evidence-led vulnerability intelligence · 2026-08-10 18:50 IST

CVE-2026-68220

In the Linux kernel, the following vulnerability has been resolved: media: nxp: imx8-isi: Add missing v4l2_subdev_cleanup() in crossbar and pipe Both mxc_isi_crossbar_init() and mxc_isi_pipe_init() call v4l2_subdev_init_finalize() which allocates the subdev active state, but neither mxc_isi_crossbar_cleanup() nor mxc_isi_pipe_cleanup() calls v4l2_subdev_cleanup() to free it. This causes a memory leak on every rmmod, reported by kmemleak: unreferenced object 0xffff0000d06fc800 (size 192): comm "(udev-worker)", pid 254, jiffies 4294913455 backtrace (crc 36eeae58): kmemleak_alloc+0x34/0x40 __kvmalloc_node_noprof+0x5f8/0x7d8 __v4l2_subdev_state_alloc+0x1fc/0x30c __v4l2_subdev_init_finalize+0x178/0x368 Add the missing v4l2_subdev_cleanup() calls before media_entity_cleanup() in both crossbar and pipe cleanup paths.

UNRATED · N/ALinux

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

N/A / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch