CVE-2026-68100
In the Linux kernel, the following vulnerability has been resolved: ksmbd: validate num_subauth when copying ACE in set_ntacl_dacl set_ntacl_dacl() copies each ACE from the attacker-controlled stored security descriptor verbatim into the response DACL without checking sid.num_subauth. The ACE bytes (including an unchecked num_subauth) originate from an authenticated SMB2_SET_INFO(SecInfo=DACL) that is stored raw via ksmbd_vfs_set_sd_xattr(); parse_dacl() rejects a bad ACE with `break` rather than an error, so parse_sec_desc() still returns success and the malformed SD reaches the xattr intact. On a subsequent SMB2_QUERY_INFO(SecInfo=DACL) for an inode carrying a POSIX access ACL, build_sec_desc() -> set_ntacl_dacl() -> set_posix_acl_entries_dacl() walks the copied ACEs and reads ntace->sid.sub_auth[ntace->sid.num_subauth - 1] with num_subauth taken straight from the stored SD. Since sub_auth[] is fixed at SID_MAX_SUB_AUTHORITIES (15), a crafted num_subauth (e.g. 255) drives an out-of-bounds heap read of ~1 KB with an offset fully controlled by an authenticated client. The sibling functions already gate this field: parse_dacl() -- num_subauth == 0 || > SID_MAX_SUB_AUTHORITIES parse_sid() -- num_subauth > SID_MAX_SUB_AUTHORITIES smb_copy_sid() -- min_t(u8, num_subauth, SID_MAX_SUB_AUTHORITIES) set_ntacl_dacl() is the lone inconsistent path that omits the check. Add the same num_subauth validation in set_ntacl_dacl() before copying the ACE, matching the gate already enforced by parse_dacl().
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.