CVE-2026-64038
In the Linux kernel, the following vulnerability has been resolved: hwmon: (lm90) Stop work before releasing hwmon device Sashiko reports: In lm90_probe(), the devm action to cancel the alert_work and report_work (lm90_restore_conf) is registered in lm90_init_client() before devm_hwmon_device_register_with_info() is called. Because devm executes cleanup actions in reverse order during module unbind or probe failure, the hwmon device is unregistered and freed first. If lm90_alert_work() or lm90_report_alarms() runs in the window between the hwmon device being freed and the delayed works being cancelled, lm90_update_alarms() will dereference the freed data->hwmon_dev here. Fix the problem by canceling the workers separately after registering the hwmon device and before registering the interrupt handler. This ensures that the workers are canceled after interrupts are disabled and before the hwmon device is released. Add "shutdown" flag to indicate that device shutdown is in progress to prevent workers from being re-armed.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.