Evidence-led vulnerability intelligence · 2026-10-15 21:48 IST

CVE-2026-63442

OPNsense is a FreeBSD based firewall and routing platform. Prior to version 26.1.11, the unauthenticated WebGUI login usernamefld accepts carriage-return and line-feed characters that survive LOG_AUTH processing through syslog-ng-lockout.conf into the syslog-ng program destination feeding lockout_handler. The consumer's readline() processing treats an injected fragment as a separate authentication event and selects the first syntactically valid IP address from the forged line. An attacker with network access to the login page can forge failure events for another IP, causing that IP to be added to the sshlockout PF table and its active states to be killed, or forge accepted events that reset an attacker's own brute-force counter. This can block administrative, DNS, gateway, or monitoring addresses and can bypass password-guessing lockout without authentication. This issue is fixed in version 26.1.11.

HIGH · 8.1Network devices

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

8.1 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch