Evidence-led vulnerability intelligence · 2026-09-05 01:47 IST

CVE-2026-61699

nebula-mesh is a self-hosted control plane for Slack Nebula mesh VPN. Prior to version 0.7.1, revocation is the only in-band mechanism that isolates a compromised/offboarded host from a Nebula mesh. Because the blocklist never reaches any peer's config.yml, a Blocked host retains full overlay reachability to every peer under its CA (and internal services on the mesh) for up to 30d (agent) / 365d (mobile). An attacker who exfiltrates host.key+host.crt can run stock slackhq/nebula directly, ignore the agent's 403/410 poll responses, and stay connected after the operator revokes the host. Operator-visible state (UI shows blocked, audit log records it) is misleading. This issue has been patched in version 0.7.1.

HIGH · 8.1Network devices

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

8.1 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch