CVE-2026-55856
MariaDB Connector/J is used to connect applications developed in Java to MariaDB and MySQL databases. Prior to 2.7.14, 3.3.5, 3.4.3, and 3.5.9, when a Java application connects with sslMode=verify-full or sslMode=verify-ca, supplies a password, and does not configure serverSslCert or trustStore, Connector/J can accept an untrusted self-signed certificate through the fallbackToSystemTrustStore=true ephemeral trust manager and record its certFingerprint for later identity binding. The OK-packet and authentication-switch paths enforce the certificate fingerprint, but the initial-handshake path does not. HandshakeResponse.encode() can therefore build and send a mysql_clear_password response before checking certFingerprint != null && !isMitMProof(), sslMode, or whether the authentication plugin is resistant to a man-in-the-middle, and the initial path also bypasses restrictedAuth. An active man-in-the-middle or hostile server can present a self-signed certificate, claim to be MariaDB, select mysql_clear_password as the initial authentication plugin, and receive the full database password before the connection is rejected. This issue is fixed in versions 2.7.14, 3.3.5, 3.4.3, and 3.5.9.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.