CVE-2026-52996
In the Linux kernel, the following vulnerability has been resolved: ksmbd: fix durable fd leak on ClientGUID mismatch in durable v2 open ksmbd_lookup_fd_cguid() returns a ksmbd_file with its refcount incremented via ksmbd_fp_get(). parse_durable_handle_context() in the DURABLE_REQ_V2 case properly releases this reference on every path inside the ClientGUID-match branch, either by calling ksmbd_put_durable_fd() or by transferring ownership to dh_info->fp for a successful reconnect. However, when an entry exists in the global file table with the same CreateGuid but a different ClientGUID, the code simply falls through to the new-open path without dropping the reference obtained from ksmbd_lookup_fd_cguid(). Per MS-SMB2 section 3.3.5.9.10 ("Handling the SMB2_CREATE_DURABLE_HANDLE_REQUEST_V2 Create Context"), the server MUST locate an Open whose Open.CreateGuid matches the request's CreateGuid AND whose Open.ClientGuid matches the ClientGuid of the connection that received the request. If no such Open is found, the server MUST continue with the normal open execution phase. A CreateGuid hit with a ClientGUID mismatch is therefore the "Open not found" case: proceeding with a new open is correct, but the reference obtained purely as a side effect of the lookup must not be leaked. Repeated requests that hit this mismatch pin global_ft entries, prevent __ksmbd_close_fd() from ever running for the corresponding files, and defeat the durable scavenger, leading to long-lived resource leaks. Release the reference in the mismatch path and clear dh_info->fp so subsequent logic does not mistake a non-matching lookup result for a reconnect target.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.