CVE-2026-47271
pam_usb provides hardware authentication for Linux using ordinary removable media. Prior to 0.9.0, src/mem.c implemented out-of-memory guards for xmalloc(), xrealloc(), and xstrdup() using assert(data != NULL). The C standard specifies that all assert() expressions are compiled out when NDEBUG is defined at build time. NDEBUG is commonly defined in release and packaging builds (Debian, Fedora, Arch package flags all define it via -DNDEBUG in CFLAGS). With the guard removed, xmalloc/xrealloc/xstrdup silently return NULL on allocation failure. Every caller in the codebase dereferences the return value without a NULL check -- this is the intended design, as the guard was supposed to abort before the dereference. With the guard gone, any allocation failure causes a NULL pointer dereference, crashing the PAM module. A crash in a PAM module loaded by sudo or login causes authentication to fail for the duration of the crash, creating a local denial-of-service condition. An attacker who can induce memory pressure at authentication time can lock all users out of sudo and login. This vulnerability is fixed in 0.9.0.
Executive briefing
A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.
Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict
Severity & attack characteristics
CVSS vector:Not supplied
No CVSS vector is currently available in the source record.
Technical explanation & impact
Technical root-cause details are not available in the current source record.
Assess the impact using the published CVSS metrics and the affected vendor component.
Affected products and versions
NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.
Remediation & validation
- Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
- Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
- Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
- Validate the remediation with a version check and vulnerability rescan, then retain change evidence.
No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.
Vendor advisories, patches & exploit references
No external references are currently supplied in the CVE record.