Evidence-led vulnerability intelligence · 2026-11-26 04:47 IST

CVE-2026-136501

To build positioned updates and to describe columns, psqlODBC matches the names in a statement against the catalog. Where it matched differently from the server, it used another table or column: - Table and schema names were compared case-insensitively in its column-information cache, so users could be taken for another user's "Users", and the driver then evaluated that table's column default to answer @@IDENTITY. - In FROM ONLY t, ONLY was taken for the table name. - Column names were compared case-insensitively, so with Parse=1 the type of another column could decide the size of the application's buffer, which a fetch then overflowed. - In a database whose encoding is single-byte, such as LATIN1 or SQL_ASCII, the server folds the accented letters of an unquoted name by its own locale, while the driver folded only A-Z, so ÉTAT could be taken for another user's "État" instead of état. - On systems other than Windows, in a Turkish or Azeri locale, an unquoted I was not folded to i, and keywords and ODBC function names did not match. - Without a schema name, SQLSpecialColumns() could report the key columns of another user's same-named temporary table, and SQLPrimaryKeys() could take another user's index named <table>_pkey for the primary key of a table without one. - After search_path changed other than through a plain SET statement, positioned writes went to the same-named table in the previously current schema. - SQLBulkOperations() trusted the ctid stored inside a variable-length bookmark handed back by the application, and ignored the WHERE clause that restricted the cursor, so a forged bookmark read, updated or deleted any row of the cursor's table. A database user who can create a table in a schema on another user's search_path can redirect that user's positioned updates, inserts and deletes to a table of their choosing, where they run with the victim's rights, or run an expression of their choosing under the victim's role. Versions up to and including psqlODBC 18.00.0006 are affected.

HIGH · 7.1Windows

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

7.1 / 10 · 3.1

CVSS vector:
CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

Attack vectorN
Attack complexityH
Privileges requiredL
User interactionR
ScopeU
Confidentiality impactH
Integrity impactH
Availability impactH

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch