Evidence-led vulnerability intelligence · 2026-11-24 13:47 IST

CVE-2026-135779

Reliance on an untrusted source of the client address in the WebSocket listener of the NetBird relay server (relay/server/listener/ws) in NetBird versions 0.31.1 through 0.74.7 allows an attacker with an enrolled peer to spoof the source address of their relay connection. The listener used the values of the X-Real-Ip and X-Real-Port request headers as the remote address of the connection unconditionally, without checking that the request came from a trusted upstream proxy. A WebSocket client that sends both headers makes the relay record and use an arbitrary address for its connection, including in the relay connection log, so a client can hide its real address or attribute its connection to another host. Only the relay server is affected; the NetBird client, including the Android and iOS apps, does not run the relay listener. The issue is fixed in version 0.75.0, which honours these headers only for requests whose direct connection address is in a configured set of trusted proxies and ignores them by default.

MEDIUM · 5.3macOS / Apple

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

5.3 / 10 · 4.0

CVSS vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Attack vectorN
Attack complexityL
Attack requirementsN
Privileges requiredL
User interactionN
ScopeX

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch