Evidence-led vulnerability intelligence · 2026-06-26 22:46 IST

CVE-2026-13434

A flaw was found in KubeVirt's network annotation generator. When a tenant creates a VirtualMachineInstance with a Multus network configuration, the supplied networkName value is written verbatim into the launcher pod's v1.multus-cni.io/default-network annotation without format validation or sanitization. The only admission check rejects empty strings; no DNS-1123 format validation, JSON detection, or special character rejection is performed. When the ExternalNetResourceInjection Beta feature gate is enabled (off by default, cluster-admin only), the NAD lookup that would otherwise catch malformed names is skipped by design. A tenant with kubevirt.io:edit permissions can inject a JSON-formatted NetworkSelectionElement array specifying an arbitrary namespace, NAD name, static IP address, and MAC address. Multus on the node parses this JSON and attaches the launcher pod to the specified network attachment in any namespace, enabling cross-namespace network access and IP/MAC impersonation on network segments normally segregated from tenant workloads. The ExternalNetResourceInjection feature gate was introduced in KubeVirt v1.8.0 (first shipped in OpenShift Virtualization 4.21).

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

4.9 / 10 · CVSS

CVSS vector:
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references