Evidence-led vulnerability intelligence · 2026-11-19 02:47 IST

CVE-2026-130090

When two templated upstreams in temporal-proxy render the same address, a request routed to one upstream can be sent under the other upstream's credential, namespace translation, and payload encryption keys. temporal-proxy pools connections for templated upstreams by rendered address and TLS server name only, although each upstream's outbound credential, namespace translation, and payload encryption keys, where configured, are attached to its connection. A request routed to one upstream can therefore be sent over the connection the other created, and the upstream Temporal service authorizes it as the other upstream's principal. Configuration validation rejects only identical hostPort values, so templates that differ in text but render the same address are accepted. This mixes the two upstreams' ordinary traffic, and a caller that an external authenticator restricts to one upstream's namespaces can use it to act under the other upstream's credential. Deployments with at most one templated upstream are not affected. temporal-proxy versions 0.1.0 through 1.1.1 are affected. The issue is fixed in 1.0.2, 1.1.2, and 1.2.0, and releases before 1.0.0 receive no fix. Upgrade to the fixed release for the deployed minor release line.

LOW · 2.3Azure / M365

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

2.3 / 10 · 4.0

CVSS vector:
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Attack vectorN
Attack complexityL
Attack requirementsP
Privileges requiredL
User interactionN
ScopeX

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch