Evidence-led vulnerability intelligence · 2026-11-11 14:47 IST

CVE-2026-126625

Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who installs the product, when it is installed into a new program folder in a location whose permissions let every user write, such as the root of a drive. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but its setup lets Inno Setup make a new program folder first, with the permissions the folder above hands down, and replaces them only afterwards, tens of milliseconds later (33 to 139 milliseconds in the project's test runs). In that time any local account may make files and folders in the new folder, which keep that account as their owner, among them the Bin folder that setup then copies the programs into. Setup runs programs from Bin with the administrator's elevated rights, registering the service among them, before its hardening at the end of setup takes such a folder back, and those programs load a library placed in Bin in place of the system's. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.

MEDIUM · 6.7Windows

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

6.7 / 10 · 3.1

CVSS vector:
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

Attack vectorL
Attack complexityH
Privileges requiredL
User interactionR
ScopeU
Confidentiality impactH
Integrity impactH
Availability impactH

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch