Evidence-led vulnerability intelligence · 2026-11-11 14:47 IST

CVE-2026-126612

Improper link resolution in the Windows installer of Progressive Robot hMailServer 6.0.0 through 6.3.7 allows a local authenticated user to run code as the mail server's service account or as an administrator when the path to the program folder passes through a junction, a symbolic link or a mount point that the user controls or that every user may change, such as a junction made at the root of a drive, which takes the root's permissions, or through a folder that every user may rename. Setup installed the programs through any such link without first checking who controls it, or whether a folder above the program folder may be renamed, and the service is registered to run the programs by that path, so the programs are installed where a link another account controls leads, or that account can later make the path lead to a folder it controls; the service, which runs as LocalSystem or as its virtual account, and the programs administrators run from Bin are then started from there. 6.3.7's fix for CVE-2026-107571 does not cover this: its hardening of the program folder, Bin and ControlPanel does not change a folder reached through a link that the administrators do not alone control, and setup does not refuse such a path: it installs through the link and at most reports afterwards that the folders could not be hardened. The default installation under Program Files is not affected.

HIGH · 7.8Windows

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

7.8 / 10 · 3.1

CVSS vector:
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Attack vectorL
Attack complexityL
Privileges requiredL
User interactionN
ScopeU
Confidentiality impactH
Integrity impactH
Availability impactH

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Open NVD record ← Back to CVE Watch