Evidence-led vulnerability intelligence · 2026-11-04 20:47 IST

CVE-2026-119776

In all prior released versions of FRRouting, the OSPFv3 (for IPv6) implementation does not check that OSPFv3 packets have a link-local source address and either a link-local destination or one of the protocol multicast destination groups. This may enable malicious actors to establish OSPFv3 adjacencies from unexpectedly, distant IPv6 hosts. Proper usage of OSPFv3 authentication trailers (RFC 7166, as is best practice) prevents full exploitation of this issue, though may allow a malicious actor to waste CPU on authentication checks. Note the linked PR #23935 is not sufficient to fix the issue as it only verifies the source address. It is the destination address that must be checked. Required configuration: The OSPFv3 for IPv6 routing protocol must be running (ospf6d process) and in use (enabled globally with "router ospf6" and on specific interfaces with "ipv6 ospf6 area".) Workaround: either: * configure OSPFv3 authentication trailers ("ipv6 ospf6 authentication") * or ensure through firewall configuration that only packets with link-local or multicast destination addresses are accepted on input for IPv6 protocol 89 (OSPF). Note that checking the source address is insufficient, as some routers may (unexpectedly) forward packets with global-scoped IPv6 destination addresses even if they have link-local source addresses.

MEDIUM · 6.1

Executive briefing

The source record describes: In all prior released versions of FRRouting, the OSPFv3 (for IPv6) implementation does not check that OSPFv3 packets have a link-local source address and either a link-local destination or one of the protocol multicast destination groups. This may enable malicious actors to establish OSPFv3 adjacencies from unexpectedly, distant IPv6 hosts. Proper usage of OSPFv3 authentication trailers (RFC 7166, as is best practice) prevents full exploitation of this issue, though may allow a malicious actor to waste CPU on authentication checks. Note the linked PR #23935 is not sufficient to fix the issue as it only verifies the source address. It is the destination address that must be checked. Required configuration: The OSPFv3 for IPv6 routing protocol must be running (ospf6d process) and in use (enabled globally with "router ospf6" and on specific interfaces with "ipv6 ospf6 area".) Workaround: either: * configure OSPFv3 authentication trailers ("ipv6 ospf6 authentication") * or ensure through firewall configuration that only packets with link-local or multicast destination addresses are accepted on input for IPv6 protocol 89 (OSPF). Note that checking the source address is insufficient, as some routers may (unexpectedly) forward packets with global-scoped IPv6 destination addresses even if they have link-local source addresses. The practical risk depends on whether an affected product/version is present, reachable and configured in an exploitable way. Review the affected-product evidence and linked vendor advisories before assigning exposure status.

Assessment: Potential exposure only — validate the installed product, exact version, configuration and vendor applicability before treating an asset as confirmed vulnerable.

Evidence confidence: Limited Evidence-derived, not an exploitability verdict

Severity & attack characteristics

6.1 / 10 · 4.0

CVSS vector:
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X

Attack vectorN
Attack complexityL
Attack requirementsP
Privileges requiredL
User interactionN
ScopeX

Technical explanation & impact

The technical mechanism is not expanded beyond the source description unless a referenced advisory supplies additional evidence. Read the linked vendor/CERT advisories for root-cause detail.

Potential impact must be interpreted from the published CVSS impact metrics and the affected component. A CVSS impact score is not proof that a particular asset is exploitable.

Weakness classification

CWE-304

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

Information gaps & confidence notes

These gaps indicate missing source data. CVE Watch does not fill them with guessed product, exploit or patch details.

Last enrichment: 2026-11-05T09:37:57+00:00 · Source last modified: 2026-11-04T17:17:35.090

Open NVD record ← Back to CVE Watch