Evidence-led vulnerability intelligence · 2026-09-26 19:46 IST

CVE-2026-100697

Adminer 6.0.0 through 6.0.1, when the official ClickHouse driver plugin (plugins/drivers/clickhouse.php, rewritten in 6.0.0) is loaded, is vulnerable to pre-authentication server-side request forgery. An unauthenticated attacker can submit auth[driver]=clickhouse with auth[server] set to an arbitrary URL (for example http://127.0.0.1:18089), causing the Adminer server to issue an HTTP POST containing 'SELECT version()' to that host. In rootQuery(), if the target returns a status outside 200-299 (other than 401/403), the raw HTTP response body is assigned to the connection error and rendered on the login page, so the attacker receives the full response body of the internal service. This enables internal network/port reconnaissance and disclosure of sensitive information contained in internal error pages (stack traces, internal hostnames, file paths, configuration identifiers). Fixed in Adminer 6.0.2.

MEDIUM · 5.3Web servers & CMS

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

5.3 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch