Evidence-led vulnerability intelligence · 2026-09-14 18:47 IST

CVE-2024-58383

Froxlor before 2.2.0 (affected up to and including 2.2.0-rc3) generates /etc/pure-ftpd/db/mysql.conf with mode 0644 via the XML configuration templates in lib/configfiles/, even though the file contains the Froxlor SQL user's password. On systems where the parent directories are world readable (the default on Debian 12), any unprivileged local user able to execute commands or code on the host — including virtual users without SSH access who can upload PHP/CGI scripts — can read the file and obtain the Froxlor database credentials. Database access can then be leveraged to alter an administrator's password hash and TOTP seed, log in as a Froxlor administrator, and ultimately gain root privileges. Only instances configured to use pure-ftpd are affected.

Executive briefing

A structured intelligence assessment has not yet been generated. The source description is shown above. The background enrichment worker will retry this record.

Assessment: Potential exposure only — validate product, version, configuration and vendor applicability.

Evidence confidence: Not assessed Evidence-derived, not an exploitability verdict

Severity & attack characteristics

8.4 / 10 · CVSS

CVSS vector:
Not supplied

No CVSS vector is currently available in the source record.

Technical explanation & impact

Technical root-cause details are not available in the current source record.

Assess the impact using the published CVSS metrics and the affected vendor component.

Affected products and versions

NVD has not supplied machine-readable vulnerable CPE product/version entries for this CVE. This is an information gap, not proof that no products are affected. Check the vendor advisory references below.

Remediation & validation

  1. Identify exposure by comparing the affected product and version ranges with your asset inventory, SBOM and externally exposed services.
  2. Review the linked vendor security advisory or patch notes. Upgrade to a vendor-confirmed fixed release; do not infer a fixed version from the CVE description.
  3. Until patched, consider restricting network access or disabling the affected feature where operationally safe. These are temporary controls, not a substitute for a vendor fix.
  4. Validate the remediation with a version check and vulnerability rescan, then retain change evidence.

No fixed version is displayed unless it is explicitly established by a vendor advisory. Follow the vendor's release notes for exact product and branch applicability.

Vendor advisories, patches & exploit references

No external references are currently supplied in the CVE record.

Open NVD record ← Back to CVE Watch